Pipe stress is caused by misalignment of the mating surfaces of two pipe flanges creating abnormal internal stress of pump bearings, seals, motor bearings, and couplings, and can possibly change the displacement of a pump.

General Rules which must be followed by maintenance personnel and contractors: (if you truly want to stop a long term pump problem)

  1. Pipe flanges attached to pumps must be aligned where the gap does not exceed the thickness of two gaskets or the tolerance established by your company’s engineering standards.
  2. Pipe flange bolts must drop in without assistance.
  3. Cable pullers, come-a-longs, or long bars should not be used when aligning a flange that is connected to a pump.
  4. Validate the elimination of pipe stress by following the guidelines listed below.

Failure Modes experienced from Pipe Stress on Bearings:

  • Wear caused by seals leaking
  • Wear caused by static vibration
  • Indentations caused by overloading while static
  • Corrosion caused by inadequate lubrication caused by abnormal loading (seal leaking)
  • Flaking caused by misalignment and excessive loading

WARNING: Ensure your contractors follow the same process to eliminate pipe stress. Pipe stress elimination should be validated during the commissioning of a new pump.

Follow this process if you want to inspect your pumps that may have pipe stress:

  1. Align the two shafts between your pump and driver (typically an electric motor) to the tolerance recommended by the equipment vendor or your company’s engineering standards.
  2. Validate misalignment to insure motor and pump shafts are aligned to specification.
  3. Disconnect the outlet flange on the pump.
  4. Revalidate laser alignment of shafts.
  5. If alignment has moved then you have pipe stress. Do the same for the inlet flange.
  6. Make corrections as stated in the following procedures to eliminate pipe stress.

Elimination of Pipe Stress – “The Ricky Smith Method for Pipe Stress” as learned from Dan Turner (his maintenance and engineering manager at Exxon during his career in the 1970s)

  1. Bolt flanges to pump and insert blind flange gasket along with two regular flanges between pump and mating flanges (cover the hole between the welding area and inside the pump).
  2. Attached welding ground to flange. (do not attach ground lead to pump; welding group must always be attached to flange) WARNING: Failure to accomplish this one task properly will cause bearing failure by “electric arcing” which is a failure mode of bearings.
  3. Tack weld flange into place reverse welding each tack.
  4. Allow cooling for 10 minutes.
  5. Reverse stitch weld on opposite sides on the flange is similarly used for cast iron welding.
  6. After initial reverse stitch weld then weld normally using electrode recommended by the American Welding Society (typically E-6010 5P or GTAW)
  7. After root pass; weld in any direction you wish.
  8. Allow to cool and then disconnect flange, replace gaskets and;
    Validate bolts will drop into holes without a pry bar.
    Validate gap between flanges is no more than two gaskets thick.

To learn more about the effects of running equipment with pipe stress, watch the LUDECA Shaft Alignment Know-How Pipe Stress tutorial video.